DocumentCode :
2948931
Title :
PD data base for stator insulation of turbogenerators
Author :
Gulski, E. ; Zondervan, J.P. ; Zielonka, A. ; Brooks, R.
Author_Institution :
High Voltage Lab., Delft Univ. of Technol., Netherlands
Volume :
2
fYear :
1997
fDate :
19-22, Oct 1997
Firstpage :
546
Abstract :
This paper discusses results of PD patterns analysis of the stator insulation in different turbogenerators. Based on these measurements a PD database has been developed to support the discharge evaluation during periodic off-line inspections of turbogenerators. Using this technique clear distinction is possible between generators in good condition and these which are showing internal or external discharges originating from the insulation degradation
Keywords :
inspection; insulation testing; machine insulation; machine testing; partial discharges; pattern recognition; stators; turbogenerators; PD database; off-line inspection; pattern analysis; stator insulation; turbogenerator; Databases; Degradation; Inspection; Insulation; Partial discharges; Pattern recognition; Shape; Stators; Turbogenerators; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1997. IEEE 1997 Annual Report., Conference on
Conference_Location :
Minneapolis, MN
Print_ISBN :
0-7803-3851-0
Type :
conf
DOI :
10.1109/CEIDP.1997.641132
Filename :
641132
Link To Document :