DocumentCode :
2950965
Title :
Evaluation of low-frequency voltage dividers, using the step response
Author :
Slomovitz, D. ; Bergalli, P. ; Daher, J.F.
Author_Institution :
UTE Lab., Montevideo, Uruguay
fYear :
1998
fDate :
6-10 July 1998
Firstpage :
319
Lastpage :
320
Abstract :
A method to characterize the behavior of low frequency voltage dividers, based on the step response, is presented. Amplitude errors and phase displacements can be evaluated, in an absolute way, without any auxiliary standard divider.
Keywords :
measurement errors; measurement uncertainty; step response; voltage dividers; voltage measurement; LF voltage dividers; amplitude errors; current shunts; impulse divider; meter input circuits; phase displacements; resistive dividers; sinusoidal waveforms; step response; uncertainty; Circuits; Frequency conversion; Instruments; Laboratories; Measurement standards; Pulse measurements; Steady-state; Voltage measurement; Voltmeters; Wattmeters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location :
Washington, DC, USA
Print_ISBN :
0-7803-5018-9
Type :
conf
DOI :
10.1109/CPEM.1998.699929
Filename :
699929
Link To Document :
بازگشت