Title :
Analytic criteria for fuses for explosive flux compression generators
Author_Institution :
Phillips Lab., Kirtland Air Force Base, NM, USA
Abstract :
An approach to optimizing the fuse opening switch geometry for explosive magnetic flux compression generators (EMGs or MCGs) is analagous to that developed by Maisonnier, Linhart, and Gourlan (1966) for inductive store/opening switch pulse sharpening of capacitor discharges. That is, the cross section of the fuses, should be related via an integral equation to the fuse material properties and the discharge current. The author investigates fuse optimisation based on the integral equation.
Keywords :
exploding wires; integral equations; optimisation; power supplies to apparatus; pulse generators; pulsed power technology; discharge current; explosive flux compression generators; fuse cross section; fuse material properties; fuse opening switch geometry; fuse optimisation; fuses; integral equation; Electromyography; Explosives; Fuses; Geometry; Integral equations; Magnetic analysis; Magnetic flux; Magnetic switching; Pulse generation; Switches;
Conference_Titel :
Pulsed Power Conference, 1995. Digest of Technical Papers., Tenth IEEE International
Conference_Location :
Albuquerque, NM, USA
Print_ISBN :
0-7803-2791-8
DOI :
10.1109/PPC.1995.599754