Title :
Development of artificial bionic baroreflex system
Author :
Sunagawa, Kenji ; Sugimachi, Masaru
Author_Institution :
Kyushu Univ., Japan
fDate :
Aug. 31 2010-Sept. 4 2010
Abstract :
The baroreflex system is the fastest mechanism in the body to regulate arterial pressure. Because the neural system (i.e., autonomic nervous system) mediates the baroreflex and the system operates under the closed-loop condition, the quantitative dynamic characteristics of the baroreflex system remained unknown until recently despite the fact that a countless number of observational and qualitative studies had been conducted. In order to develop the artificial baroreflex system, i.e., the bionic baroreflex system, we first anatomically isolated the carotid sinuses to open the baroreflex loop and identified the open-loop transfer function of the baroreflex system using white noise pressure perturbations. We found that the baroreflex system is basically a lowpass filter and remarkably linear. As an actuator to implement the bionic baroreflex system, we then stimulated the sympathetic efferent nerves at various parts of the baroreflex loop and identified the transfer functions from the stimulation sites to systemic arterial pressure. We found that the actuator responses can be described remarkably well with linear transfer functions. Since transfer functions of the native baroreflex and of the actuator were identified, the controller that is required to reproduce the native baroreflex transfer function can be easily derived from those transfer functions. To examine the performance of bionic baroreflex system, we implemented it animal models of baroreflex failure. The bionic baroreflex system restored normal arterial pressure regulation against orthostatic stresses that is indistinguishable from the native baroreflex system.
Keywords :
actuators; biocybernetics; biomedical equipment; blood pressure measurement; blood vessels; physiological models; transfer functions; actuator; animal models; arterial pressure regulation; artificial bionic baroreflex system; autonomic nervous system; carotid sinuses; closed-loop condition; lowpass filter; neural system; open-loop transfer function; orthostatic stresses; quantitative dynamic characteristics; white noise pressure perturbations; Actuators; Animals; Baroreflex; Resonant frequency; Stress; Transfer functions; Baroreflex; Biomimetics; Bionics; Blood Pressure; Electric Stimulation Therapy; Equipment Design; Equipment Failure Analysis; Heart; Humans; Male; Sympathetic Nervous System;
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
Conference_Location :
Buenos Aires
Print_ISBN :
978-1-4244-4123-5
DOI :
10.1109/IEMBS.2010.5627863