DocumentCode :
2959003
Title :
Experimental ablation processes study on an electrothermal launcher
Author :
Veron, Laurent ; Noiret, Pierre ; Roux, Serge
Author_Institution :
CEA, Centre d´´Etudes de Vaujours-Moronvilliers, Courtry, France
Volume :
2
fYear :
1995
fDate :
3-6 July 1995
Firstpage :
1291
Abstract :
An experimental parametric study has been performed to analyse the influence of time on the ablation processes in the capillary of an electrothermal launcher. A 600 kJ, 16 cells pulse forming network (PFN) was used. The time discharge was varied from 350 /spl mu/s to 100 /spl mu/s by changing the cell number (from 16 to 4) and then the capacitance (from 1760 /spl mu/F to 440 /spl mu/F). The parametric study has been performed at a constant voltage level (13 kV). The ablated masses have been measured for different time discharge and the results have been compared with a 0-D code.
Keywords :
discharges (electric); electrothermal launchers; power capacitors; power supplies to apparatus; pulse generators; pulsed power switches; surface phenomena; 13 kV; 1760 to 440 muF; 350 to 100 mus; 600 kJ; ablation processes; electrothermal launcher; parametric study; pulse forming network; time discharge; Capacitance; Electrodes; Electrothermal effects; Electrothermal launching; Fault location; Parametric study; Projectiles; Pulsed power supplies; Transducers; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 1995. Digest of Technical Papers., Tenth IEEE International
Conference_Location :
Albuquerque, NM, USA
Print_ISBN :
0-7803-2791-8
Type :
conf
DOI :
10.1109/PPC.1995.599794
Filename :
599794