DocumentCode :
2960162
Title :
An unified method for estimating the parameters of non-isolated DC/DC converters using continuous time models
Author :
Buiatti, Gustavo M. ; Amaral, Acacio M R ; Cardoso, A. J Marques
Author_Institution :
Alstom Transp., Semeac
fYear :
2007
fDate :
Sept. 30 2007-Oct. 4 2007
Firstpage :
334
Lastpage :
341
Abstract :
In this paper, a novel online technique used for estimating the parameters of non-isolated buck, boost and buck-boost DC/DC converters is presented. Continuous time models of each converter are used in the estimation procedure, where the derivative calculation problem of needed signals is solved by polynomial interpolation. Least mean squares algorithm is then applied together with other calculations. The knowledge of these parameters may be used in the fault diagnosis of such converters. Results obtained from simulations are presented, followed by experimental results in which the inductance, capacitance, load resistor and ESR of the capacitor are estimated, in order to validate the proposed technique.
Keywords :
DC-DC power convertors; fault diagnosis; interpolation; least mean squares methods; polynomials; buck-boost DC-DC converters; continuous time models; fault diagnosis; least mean squares algorithm; non-isolated DC-DC converters; non-isolated buck converters; polynomial interpolation; Capacitance; Continuous time systems; DC-DC power converters; Fault diagnosis; Inductance; Interpolation; Least mean square algorithms; Parameter estimation; Polynomials; Resistors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Telecommunications Energy Conference, 2007. INTELEC 2007. 29th International
Conference_Location :
Rome
Print_ISBN :
978-1-4244-1627-1
Electronic_ISBN :
978-1-4244-1628-8
Type :
conf
DOI :
10.1109/INTLEC.2007.4448794
Filename :
4448794
Link To Document :