Title :
Research on Measurement of POF Attenuation Spectrum
Author :
Chunyuan, Feng ; Zhongyang, Rao
Author_Institution :
Shandong Jiao Tong Univ., Ji´´nan, China
Abstract :
Truncation is an efficient way to measure attenuation spectrum of PMMA and PS, and we set up the systems measuring the attenuation of POF. The position of low loss can be discovered, therefore we not only can choose suitable transmission windows and suitable pump sources, but also use wavelength division multiplexing (WDM) to settle bandwidth problem. We analyze the attenuation spectrum and make a comparison between PMMA and PS fiber. Three windows of PMMA are 520 nm, 574 nm and 650 nm. The window at 650 nm is usually used. The loss at 520 nm, 574 nm is smaller and the attenuation spectrum is flatter, so this window will be used better. PS fiber has been found existing six windows. There are 550 nm, 580 nm, 630 nm, 670 nm, 733 nm and 780 nm in the range of measurement. Two windows of 550n m and 580 nm are suitable for exploring.
Keywords :
attenuation measurement; optical fibre communication; optical variables measurement; wavelength division multiplexing; PMMA attenuation spectrum; POF attenuation spectrum measurement; PS fiber; WDM; bandwidth problem; wavelength 520 nm; wavelength 550 nm; wavelength 574 nm; wavelength 580 nm; wavelength 630 nm; wavelength 650 nm; wavelength 670 nm; wavelength 733 nm; wavelength 780 nm; wavelength division multiplexing; Absorption; Attenuation; Loss measurement; Optical fiber communication; Optical fiber devices; Optical fibers; Propagation losses; Attenuation Spectrum; PMMA; POF; PS;
Conference_Titel :
Intelligent Computation Technology and Automation (ICICTA), 2011 International Conference on
Conference_Location :
Shenzhen, Guangdong
Print_ISBN :
978-1-61284-289-9
DOI :
10.1109/ICICTA.2011.453