DocumentCode
2965292
Title
Capacitance intercomparison between NML (South Africa) and NPL (India) and NML (South Africa) and NMi (Netherlands)
Author
Moodley, S.S. ; Van Oostrom, B. ; Temba, M.L. ; Marais, E.L.
Author_Institution
Nat. Metrol. Lab., CSIR, Pretoria, South Africa
fYear
1998
fDate
6-10 July 1998
Firstpage
496
Lastpage
497
Abstract
The National Metrology Laboratory (NML) of South Africa carried out two independent capacitance intercomparisons with the Nederlands Meetinstituut (NMi) of the Netherlands and the National Physical Laboratory (NPL) of India during the latter part of 1997. The paper gives the results of the intercomparison and the capacitance measurement systems prevalent in the laboratories involved.
Keywords
calibration; capacitance measurement; capacitors; measurement standards; 10 pF; calibration; capacitance bridge; capacitance intercomparison; international intercomparison; measurement systems; national standards; reference capacitor; traceability; Africa; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Dielectric measurements; Laboratories; Measurement standards; Measurement uncertainty; Metrology;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.700023
Filename
700023