• DocumentCode
    2965292
  • Title

    Capacitance intercomparison between NML (South Africa) and NPL (India) and NML (South Africa) and NMi (Netherlands)

  • Author

    Moodley, S.S. ; Van Oostrom, B. ; Temba, M.L. ; Marais, E.L.

  • Author_Institution
    Nat. Metrol. Lab., CSIR, Pretoria, South Africa
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    496
  • Lastpage
    497
  • Abstract
    The National Metrology Laboratory (NML) of South Africa carried out two independent capacitance intercomparisons with the Nederlands Meetinstituut (NMi) of the Netherlands and the National Physical Laboratory (NPL) of India during the latter part of 1997. The paper gives the results of the intercomparison and the capacitance measurement systems prevalent in the laboratories involved.
  • Keywords
    calibration; capacitance measurement; capacitors; measurement standards; 10 pF; calibration; capacitance bridge; capacitance intercomparison; international intercomparison; measurement systems; national standards; reference capacitor; traceability; Africa; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Dielectric measurements; Laboratories; Measurement standards; Measurement uncertainty; Metrology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1998 Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-5018-9
  • Type

    conf

  • DOI
    10.1109/CPEM.1998.700023
  • Filename
    700023