Abstract :
Turkish and German Metrology Institutes (UME and PTB) performed an intercomparison of 10 mH inductance standards at 1 kHz. The measurements of the thermostatically-controlled transfer standard of PTB were taken by new Maxwell-Wien bridge with a Wagner arm made in UME. Relative difference of UME and PTB measurements on the same standard was found to be 5.10/sup -6/. Results have shown that this type of Maxwell-Wien bridge is capable of producing very precise measurements on standard inductors and promised further developments that will increase the accuracy of the system.
Keywords :
bridge circuits; calibration; inductance measurement; inductors; transfer standards; Maxwell-Wien bridge; UME-PTB intercomparison; Wagner arm; inductance standards; international intercomparison; precise measurements; relative differences; standard inductors; thermostatically-controlled transfer standard; traceability; zero substitution method; Bridge circuits; Capacitance; Capacitors; Electrical resistance measurement; Inductance measurement; Inductors; Measurement standards; Resistors; Standards development; Temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location :
Washington, DC, USA
Print_ISBN :
0-7803-5018-9
Type :
conf
DOI :
10.1109/CPEM.1998.700024
Filename :
700024
Link To Document :
بازگشت