Abstract :
This paper focuses on the experimental investigation for incipient fault detection and fault detection methods suitably adapted for use in permanent-magnet motors for direct-drive elevator systems. The proposed system diagnoses permanent-magnet motors having two types of faults such as short circuit of stator windings and bearing fault. After processing current data the classical fast Fourier transform is applied to detect characteristics under the healthy and various faulted conditions with MCSA.
Keywords :
fast Fourier transforms; fault diagnosis; lifts; machine bearings; machine testing; permanent magnet motors; short-circuit currents; stators; synchronous motors; bearing fault; direct-drive elevator systems; fast Fourier transforms; fault detection; machine current signature analysis; permanent magnet synchronous motor; short circuit fault; stator windings; Circuit faults; Current measurement; DC motors; Elevators; Fault detection; Magnetic analysis; Permanent magnet motors; Synchronous motors; Traction motors; Velocity measurement; elevator systems; fault diagnosis; permanent-magnet motors; signature analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines, 2008. ICEM 2008. 18th International Conference on
Conference_Location :
Vilamoura
Print_ISBN :
978-1-4244-1735-3
Electronic_ISBN :
978-1-4244-1736-0
Type :
conf
DOI :
10.1109/ICELMACH.2008.4799863
Filename :
4799863
Link To Document :
بازگشت