    Performance analysis of permanent magnet synchronous motor drives under inverter fault conditions

  • Author

    Estima, Jorge O. ; Cardoso, A. J Marques

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Coimbra, Coimbra
  • fYear
    2008
  • fDate
    6-9 Sept. 2008
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper presents a comparative study regarding the performance of a permanent magnet synchronous motor drive, under normal and faulty operating conditions. Two different failure types in the inverter are considered: single power switch and single phase open-circuit faults. In order to compare the drive performance under these three operating conditions, global results are presented concerning the analysis of some key parameters like motor efficiency, power factor, electromagnetic torque and currents RMS and total harmonic distortion values.
  • Keywords
    invertors; permanent magnet motors; synchronous motor drives; inverter fault conditions; permanent magnet synchronous motor drives; single phase open-circuit faults; single power switch; Drives; Electromagnetic analysis; Harmonic analysis; Inverters; Magnetic analysis; Performance analysis; Permanent magnet motors; Reactive power; Synchronous motors; Torque;