Thin-film multijunction thermal converters have been introduced as primary AC-DC voltage transfer standards at KRISS. The evaluation of the standards from an extensive series of comparisons and analysis of the error sources by using a new automatic AC-DC difference measurement system and the fast-reversed DC source is described. The agreement between the two systems is better than 1 ppm up to 4 V and 10 kHz.
Keywords :
calibration; convertors; measurement uncertainty; transfer standards; voltage measurement; 10 kHz; 4 V; KRISS standard re-establishment; automatic AC-DC difference measurement; calibration; dissemination; error sources; fast-reversed DC source; maintenance; primary AC voltage standard; thin-film multijunction thermal converters; transfer standards; two-channel system; uncertainty; voltage dropping resistors; Analog-digital conversion; Calibration; Error analysis; Frequency measurement; Instruments; Measurement standards; Testing; Transistors; Voltage; Wire;