DocumentCode :
2967337
Title :
Method of Noise Reduction for High-Voltage Systems Applied in Subsea Plants
Author :
Hyeok-Joon Kwon ; Jae-Woo Yoon ; Hong Cho ; Seung-Jae Ryu ; Byeong-Woo Kim
Author_Institution :
Grad. Sch. of Electr. Eng., Univ. of Ulsan, Ulsan, South Korea
fYear :
2013
fDate :
16-18 Dec. 2013
Firstpage :
1
Lastpage :
4
Abstract :
This paper is conducted a research of the cable and filter design considering the deep sea floor environment. The electric architecture which is being used in the subsea plant is comprised of the power supply unit of the high voltage, high-capacity drive system, long cable, and electric motor in the sea area. Conducted emission is occurred by the rapid voltage change at the moment of switching at high speed of inverter for driving motors. The more the length of the cable is lengthened, the worse the motor is influenced by transient voltage. Thus, the over voltage occurred in the drive motor was confirmed by designed wire which is considered R, L, line-to-line C, line-to-gnd C of long cable used in the subsea plant. A guide line of the subsea plant model is also suggested by using a filter to reduce conducted noise of PWM inverter drive-system.
Keywords :
AC motor drives; electromagnetic interference; invertors; low-pass filters; noise abatement; offshore installations; submarine cables; PWM inverter drive-system; cable design; conducted emission; deep sea floor environment; driving motors; electric architecture; electric motor; filter design; high-capacity drive system; high-voltage systems; long cable; noise reduction method; over voltage; power supply unit; sea area; subsea plants; Analytical models; Electric motors; Inverters; Mathematical model; Noise; Power cables; Pulse width modulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IT Convergence and Security (ICITCS), 2013 International Conference on
Conference_Location :
Macao
Type :
conf
DOI :
10.1109/ICITCS.2013.6717853
Filename :
6717853
Link To Document :
بازگشت