Title :
Range winding for wide input range front end DC/DC converter
Author :
Yang, Bo ; Xu, Peng ; Lee, Fred C.
Author_Institution :
Bradley Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
Abstract :
Hold up time requirement is a special requirement for a front end (FE) converter. The converter needs to provide output voltage within regulation for 20 ms after the AC input is lost. When designing the FE DC/DC converter, we want it to operate over a wide input range so that we can use less high voltage bus capacitor to meet the requirement. The converter efficiency is reduced at normal operating conditions, in order to cover wide input range. This paper demonstrates a new method to cover wide input range while also optimizing the normal condition operation with range winding
Keywords :
DC-DC power convertors; windings; converter efficiency; front end DC/DC converter; normal condition operation optimisation; output voltage; range winding; wide input range front end DC/DC converter; Bridge circuits; Capacitors; DC-DC power converters; Iron; Optimization methods; Power electronics; Power generation; Power system reliability; Power systems; Voltage;
Conference_Titel :
Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual IEEE
Conference_Location :
Anaheim, CA
Print_ISBN :
0-7803-6618-2
DOI :
10.1109/APEC.2001.911689