DocumentCode
2968731
Title
Range winding for wide input range front end DC/DC converter
Author
Yang, Bo ; Xu, Peng ; Lee, Fred C.
Author_Institution
Bradley Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
Volume
1
fYear
2001
fDate
2001
Firstpage
476
Abstract
Hold up time requirement is a special requirement for a front end (FE) converter. The converter needs to provide output voltage within regulation for 20 ms after the AC input is lost. When designing the FE DC/DC converter, we want it to operate over a wide input range so that we can use less high voltage bus capacitor to meet the requirement. The converter efficiency is reduced at normal operating conditions, in order to cover wide input range. This paper demonstrates a new method to cover wide input range while also optimizing the normal condition operation with range winding
Keywords
DC-DC power convertors; windings; converter efficiency; front end DC/DC converter; normal condition operation optimisation; output voltage; range winding; wide input range front end DC/DC converter; Bridge circuits; Capacitors; DC-DC power converters; Iron; Optimization methods; Power electronics; Power generation; Power system reliability; Power systems; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition, 2001. APEC 2001. Sixteenth Annual IEEE
Conference_Location
Anaheim, CA
Print_ISBN
0-7803-6618-2
Type
conf
DOI
10.1109/APEC.2001.911689
Filename
911689