DocumentCode
2969213
Title
An improved harmonic detection based on lead compensation for active power filter
Author
Xu, Jun ; Chen, Min ; Ju, Jianyong ; Dehong Xu
Author_Institution
Electr. Eng. Dept, ZheJiang Univ., Hangzhou
fYear
2008
fDate
17-20 Aug. 2008
Firstpage
1
Lastpage
6
Abstract
Active power filter (APF) with digital control is widely used to solve harmonic problems. But inherent delay time introduced by digital control significantly affects the performance of APF. Here, we introduce an improved harmonic detection method by using phase-shifting. In order to shorten the computation time of harmonics reference, we use the data calculated in the last sample period. So the delay time is shortened, and the performance of APF is improved. The whole algorithm is based on generalized instantaneous reactive power theory. This method is easy to realize and useful for industrial application. A 50 kVA three-phase four-wire shunt active power filter is implemented. The controllers with two types of TI digital signal processors (TMS320LF240 and TMS320F2812) are compared. Experiment result shows good performance employing the new algorithm for APF.
Keywords
active filters; digital control; harmonic analysis; power filters; reactive power; TI digital signal processors; apparent power 50 kVA; digital control; harmonic detection; industrial application; instantaneous reactive power theory; lead compensation; phase-shifting; three-phase four-wire shunt active power filter; Active filters; Delay effects; Digital control; Digital signal processors; IEC standards; Power harmonic filters; Power system harmonics; Pulse width modulation; Reactive power; Signal processing algorithms;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Modeling for Power Electronics, 2008. COMPEL 2008. 11th Workshop on
Conference_Location
Zurich
Print_ISBN
978-1-4244-2550-1
Electronic_ISBN
978-1-4244-2551-8
Type
conf
DOI
10.1109/COMPEL.2008.4634707
Filename
4634707