DocumentCode
2970172
Title
Analysis and calculation of systemic error of voltage difference method in the calibration for heavy DC sensors
Author
Shiyan Ren ; Zhijie Zhang ; Wenyi Hu
Author_Institution
Dept. of Electr. Eng., Huazhong Univ. of Sci. & Technol., Wuhan, China
fYear
1998
fDate
6-10 July 1998
Firstpage
568
Lastpage
569
Abstract
A method of analyzing and calculating the systemic error of the voltage difference method in the calibration for heavy DC sensors is developed. For both current-voltage sensor and current-current sensor, the expressions for their systematic error are derived. The definitions of the methodical error are discussed. The rules for the reasonable selection of parameters of the equipment used for the calibration system are given.
Keywords
calibration; current comparators; electric current measurement; electric sensing devices; measurement errors; calibration; current-current sensor; current-voltage sensor; definitions; heavy DC sensors; methodical error; reasonable selection of parameters; systematic error; systemic error; voltage difference method; Calibration; Circuits; Current measurement; Electrical resistance measurement; Equations; Gold; Measurement standards; Sensor systems; Sensor systems and applications; Voltage;