DocumentCode :
2970406
Title :
Thermal evaluation of TEFC three-phase induction motors under different supply frequencies
Author :
Mendes, A.M.S. ; Lopez-Fernandez, Xose M. ; Cardoso, A. J Marques
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Coimbra, Coimbra
fYear :
2008
fDate :
6-9 Sept. 2008
Firstpage :
1
Lastpage :
6
Abstract :
Improvements in motor protection and design require knowledge of the thermal effects produced in a motor when it is operating under normal and abnormal conditions. This paper describes a series of experimental tests that were conducted on a 4 kW total enclosed fan cooled (TEFC) three-phase induction motor. The tests were carried out when the motor is supplied by both voltage source inverter and sinusoidal voltage source, considering the influence of the ventilation. A comprehensive picture of steady-state and transient temperatures of both stator and rotor is presented.
Keywords :
induction motors; invertors; TEFC three-phase induction motors; motor protection; sinusoidal voltage source; thermal effects; thermal evaluation; total enclosed fan cooled motor; transient temperatures; voltage source inverter; Frequency; Induction motors; Inverters; Protection; Stators; Steady-state; Temperature; Testing; Ventilation; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines, 2008. ICEM 2008. 18th International Conference on
Conference_Location :
Vilamoura
Print_ISBN :
978-1-4244-1735-3
Electronic_ISBN :
978-1-4244-1736-0
Type :
conf
DOI :
10.1109/ICELMACH.2008.4800075
Filename :
4800075
Link To Document :