DocumentCode
2970994
Title
Comparison of measured and analytically calculated stray load losses in standard cage induction machines
Author
Hagen, A.R. ; Binder, A. ; Aoulkadi, M. ; Knopik, T. ; Bradley, K.
Author_Institution
Inst. of Electr. Energy Conversion, Darmstadt Univ. of Technol., Darmstadt
fYear
2008
fDate
6-9 Sept. 2008
Firstpage
1
Lastpage
6
Abstract
An analytical approach to calculate the stray load losses of cage induction machines at sinusoidal supply is compared with input-output measurements according to IEC 61972, which complies with the new standard IEC 60034-2, 4.0 ed. under preparation. The analytical approach allows the calculation of losses in the stator winding due to current displacement, due to harmonic rotor and inter-bar currents, due to tooth flux pulsations and eddy currents in the rotor surface, at any given slip, load and saturation level. Calculation and measurements are compared for 4-pole TEFC standard induction motors 1.1 kW, 11 kW, 75 kW and 110 kW.
Keywords
eddy current losses; squirrel cage motors; stators; 4-pole TEFC standard induction motors; cage induction machines; eddy currents; harmonic rotor; inter-bar currents; power 1.1 kW; power 11 kW; power 110 kW; power 75 kW; stator winding; stray load losses; tooth flux pulsations; Eddy currents; Harmonic analysis; IEC standards; Induction machines; Induction motors; Loss measurement; Measurement standards; Rotors; Stator windings; Teeth;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines, 2008. ICEM 2008. 18th International Conference on
Conference_Location
Vilamoura
Print_ISBN
978-1-4244-1735-3
Electronic_ISBN
978-1-4244-1736-0
Type
conf
DOI
10.1109/ICELMACH.2008.4800102
Filename
4800102
Link To Document