• DocumentCode
    2970994
  • Title

    Comparison of measured and analytically calculated stray load losses in standard cage induction machines

  • Author

    Hagen, A.R. ; Binder, A. ; Aoulkadi, M. ; Knopik, T. ; Bradley, K.

  • Author_Institution
    Inst. of Electr. Energy Conversion, Darmstadt Univ. of Technol., Darmstadt
  • fYear
    2008
  • fDate
    6-9 Sept. 2008
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    An analytical approach to calculate the stray load losses of cage induction machines at sinusoidal supply is compared with input-output measurements according to IEC 61972, which complies with the new standard IEC 60034-2, 4.0 ed. under preparation. The analytical approach allows the calculation of losses in the stator winding due to current displacement, due to harmonic rotor and inter-bar currents, due to tooth flux pulsations and eddy currents in the rotor surface, at any given slip, load and saturation level. Calculation and measurements are compared for 4-pole TEFC standard induction motors 1.1 kW, 11 kW, 75 kW and 110 kW.
  • Keywords
    eddy current losses; squirrel cage motors; stators; 4-pole TEFC standard induction motors; cage induction machines; eddy currents; harmonic rotor; inter-bar currents; power 1.1 kW; power 11 kW; power 110 kW; power 75 kW; stator winding; stray load losses; tooth flux pulsations; Eddy currents; Harmonic analysis; IEC standards; Induction machines; Induction motors; Loss measurement; Measurement standards; Rotors; Stator windings; Teeth;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines, 2008. ICEM 2008. 18th International Conference on
  • Conference_Location
    Vilamoura
  • Print_ISBN
    978-1-4244-1735-3
  • Electronic_ISBN
    978-1-4244-1736-0
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2008.4800102
  • Filename
    4800102