DocumentCode :
2973247
Title :
A Hybrid Active Compensation Method for Current Balance Based on Y,d11 Connection Traction Transformer
Author :
Guo, Wang ; Enen, Ren ; Mingxing, Tian
Author_Institution :
Sch. of Autom. & Electr. Eng., Lanzhou Jiatong Univ., Lanzhou
fYear :
2008
fDate :
2-3 Aug. 2008
Firstpage :
582
Lastpage :
586
Abstract :
Electrified railway traction loads present large single phase loads to the supply system. Most of traction transformer use Y,d11 connection in china. Typically zero sequence components are removed using a phase to phase transformer connection, however a large negative sequence component remains. With the developing of high speed and heavy load of the train, low power factor, high contents of harmonic currents, and negative-sequence current in traction power systems become more critical. This paper presents a novel hybrid compensation method to compensate reactive power, harmonic, and negative-sequence currents in two feeders of a traction substation. The system structure of current balance compensator method is constituted by an AC-DC-AC single-phase inverter, base frequency and high-frequency harmonic passive filter to suppress harmonic current, negative-sequence current and reactive current. It detects the active current difference of two phase traction loads, and then makes active power flows from the light load side to the heavy side through the compensator. The result is two phase traction loads of the transformer reach to balance state to insure the current symmetry of three-phase side of the Y,d11 connection traction transformer.
Keywords :
electric current control; invertors; railway electrification; substations; traction power supplies; transformers; AC-DC-AC single-phase inverter; Y,d11 connection traction transformer; electrified railway traction; harmonic passive filter; hybrid active compensation method; negative-sequence current; phase to phase transformer; reactive current; suppress harmonic current; traction power systems; traction substation; Frequency; Hybrid power systems; Inverters; Phase transformers; Power harmonic filters; Power system harmonics; Rail transportation; Railway electrification; Reactive power; Substations; Current Balance Compensation; Electrified railway; Y; d11 connection traction transformer; passive filter; single-phase inverter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Intelligent Transportation System, 2008. PEITS '08. Workshop on
Conference_Location :
Guangzhou
Print_ISBN :
978-0-7695-3342-1
Type :
conf
DOI :
10.1109/PEITS.2008.88
Filename :
4634922