• DocumentCode
    2977233
  • Title

    New measurement capabilities of the NRC travelling standard program

  • Author

    Arseneau, R. ; Filipski, P. ; Zelle, J.

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    609
  • Lastpage
    610
  • Abstract
    The paper describes the improvements made to the NRC Watt-VA Transfer Standard and AC Source which are used to support the NRC Travelling Standard Program. With these improvements, NRC clients can now calibrate on site the voltage, current, active, reactive and apparent power functions of their standards for voltages of up to 600 V and currents of up to 50 A.
  • Keywords
    calibration; power measurement; reactive power; transfer standards; volt-ampere meters; wattmeters; 50 A; 600 V; AC source; NRC travelling standard program; active power function; apparent power function; current transformer; on-site calibration; range extenders; reactive power function; reference meter; traceability; utility standards; watt-VA transfer standard; Calibration; Councils; Current transformers; Government; Imaging phantoms; Measurement standards; Potentiometers; Reactive power; Testing; Voltage transformers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1998 Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-5018-9
  • Type

    conf

  • DOI
    10.1109/CPEM.1998.700104
  • Filename
    700104