Traceability and uncertainty of field-strength measurements
Author
Glimm, J. ; Munter, K. ; Pape, R. ; Spitzer, M. ; Schrader, Th.
Author_Institution
Phys. Tech. Bundesanstalt, Braunschweig, Germany
fYear
1998
fDate
6-10 July 1998
Firstpage
636
Lastpage
637
Abstract
A new electromagnetic field-strength standard generator up to 1 GHz has been set up at PTB by means of a /spl mu/TEM-cell (septum-height 35 mm), a field-sensor transfer-standard, and a GTEM-cell as working standard for calibrations and EMC-testing, to guarantee traceability of field-strength measurement to the basic SI-units including uncertainty figures.
Keywords
calibration; electromagnetic compatibility; field strength measurement; measurement uncertainty; transfer standards; /spl mu/TEM-cell; EM field-strength standard generator; EMC-testing; GTEM-cell; SI-units; calibration chain; calibrations; field-sensor transfer-standard; field-strength measurements; traceability; uncertainty; Abstracts; Calibration; Electromagnetic fields; Electromagnetic measurements; Europe; Measurement standards; Measurement uncertainty; Power generation; Power measurement; Testing;