DocumentCode :
2978721
Title :
Maximum frequency for hysteretic control COT buck converters
Author :
Wong, L.K. ; Man, T.K.
Author_Institution :
Power Manage. Design Center, Nat. Semicond. Corp., Hong Kong
fYear :
2008
fDate :
1-3 Sept. 2008
Firstpage :
475
Lastpage :
478
Abstract :
There are many analyses on the closed-loop performance for COT buck converters. But all of them assume the absence of the multiple pulsing effect, which will increase the output voltage and inductor current swing significantly, and a poor steady state performance is as a result. This paper presents a time domain analysis for COT buck converters to show the relationship between the multiple pulsing effect and the on-time. Results indicate a minimum limit for the on-time that can avoid the multiple pulsing effect, and consequently the maximum frequency with good steady state performance can be found.
Keywords :
power convertors; closed-loop performance; hysteretic control COT buck converters; inductor current swing; Buck converters; Circuits; Energy management; Frequency conversion; Hysteresis; Inductors; Steady-state; Switches; Time domain analysis; Voltage control; Converter control; DC power supply; power management;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Motion Control Conference, 2008. EPE-PEMC 2008. 13th
Conference_Location :
Poznan
Print_ISBN :
978-1-4244-1741-4
Electronic_ISBN :
978-1-4244-1742-1