• DocumentCode
    2980257
  • Title

    Time Base Correction Technique in Antenna Time Domain Planar Near Field Measurement

  • Author

    Wang, Nan ; Xue, Zheng-hui ; Yang, Shing-ming ; Liu, Ruixiang ; Xu, Xiaowen

  • Author_Institution
    Beijing Inst. of Technol., Beijing
  • fYear
    2007
  • fDate
    18-21 April 2007
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In the practice of antenna time domain planar near field measurement, the pulse generator´s time base joggling can cause very big errors in measuring results. In this paper, a time base correction technique is developed to deal with this problem. Besides measuring channel, this technique adds a reference channel in measuring system, and uses the reference channel´s time base joggling to correct the measuring channel´s signal. The practical measuring results have proved this method´s reliability.
  • Keywords
    planar antennas; time-domain analysis; antenna time domain planar near field measurement; measuring channel signal; pulse generator time base joggling; reference channel time base joggling; time base correction technique; Antenna measurements; Directional couplers; Error correction; Oscilloscopes; Pulse generation; Pulse measurements; Sampling methods; Signal generators; Signal processing; Time measurement; antenna measurement system; planar near field; time base correction; time domain;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave and Millimeter Wave Technology, 2007. ICMMT '07. International Conference on
  • Conference_Location
    Builin
  • Print_ISBN
    1-4244-1049-5
  • Electronic_ISBN
    1-4244-1049-5
  • Type

    conf

  • DOI
    10.1109/ICMMT.2007.381291
  • Filename
    4266050