DocumentCode
2981098
Title
Research on Motion of Specimen of Ultrasonic Feeding Device
Author
Li, Liang ; He, Qing ; Wang, Yan
Author_Institution
Dept. of Math. & Phys. Sci., Liaoning Univ. of Technol., Jinzhou, China
fYear
2010
fDate
25-27 June 2010
Firstpage
2944
Lastpage
2947
Abstract
In this paper, a theoretical model is established, which describes the motion of the specimen of the ultrasonic feeding device. By using this model, the nonlinear contact force between the specimen and the oscillator, the tangential displacement and the tangential velocity of the specimen can be calculated, and then tangential motion and the normal motion of the specimen can be analyzed. Finally, this model is used to explain the experimental result of the impact of the specimen on the cantilever.
Keywords
cantilevers; materials handling equipment; ultrasonic devices; cantilever; nonlinear contact force; specimen motion; tangential displacement; tangential velocity; ultrasonic feeding device; Acoustics; Aerospace engineering; Mathematical model; Oscillators; Rough surfaces; Tribology; Vibrations; nonlinear contact; oscillator; ultrasonic feeding device;