Title :
Shielding Effectiveness of a Rectangular Enclosure with Aperture and Wire Penetration
Author :
Sapuan, Syarfa Zahirah ; Jenu, Mohd Zarar Mohd
Author_Institution :
Kolej Univ. Teknologi Tun Hussein Onn, Johor
Abstract :
An enclosure without aperture and wire penetration are impracticable due to the requirement for ventilation and cables. This paper is written to present the measurement of shielding effectiveness (SE) and S21 for such enclosure at frequencies below 1 GHz. The measurement results indicate that a wire or cable penetrating into an enclosure has impact to the shielding effectiveness. The coupling between a wire penetration and a detector inside the enclosure show good agreement between experiment and simulation. All results indicate the same resonant frequency approximately 707.1 MHz for a 300 times 120 times 300 mm enclosure.
Keywords :
electromagnetic coupling; electromagnetic shielding; wires; electromagnetic scheilding effectiveness; rectangular enclosure; resonant frequency; wire penetration; Antenna measurements; Apertures; Cables; Electromagnetic compatibility; Electromagnetic interference; Electromagnetic measurements; Electromagnetic radiation; Frequency measurement; Ventilation; Wire;
Conference_Titel :
Microwave and Millimeter Wave Technology, 2007. ICMMT '07. International Conference on
Conference_Location :
Builin
Print_ISBN :
1-4244-1049-5
Electronic_ISBN :
1-4244-1049-5
DOI :
10.1109/ICMMT.2007.381376