The vacuum vessel of RFX has been designed to operate between room temperature and 350°C during experimental sessions and during first wall conditioning operations. The temperature control system of the vacuum vessel consists of the measurement and the heating systems, connected to the RFX central control system, SIGMA. The data acquisition electronics supplies the temperature signals to the heating system and to SIGMA. The heating system provides uniform heating in both toroidal and poloidal directions. SIGMA allows different modes of operation and handles the alarm signals. After a description of the main components, the results of the first two years of operation are presented
Keywords
data acquisition; fusion reactor design; fusion reactor instrumentation; plasma-wall interactions; reversed field pinch; temperature control; 20 to 350 C; RFX; RFX central control system; SIGMA; alarm signals; data acquisition electronics; first wall conditioning operations; heating systems; poloidal directions; toroidal directions; vacuum vessel temperature control; Cable insulation; Cable shielding; Centralized control; Control systems; Cooling; Heating; Plasma temperature; Temperature control; Temperature measurement; Temperature sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1993., 15th IEEE/NPSS Symposium on
Conference_Location
Hyannis, MA
Print_ISBN
0-7803-1412-3
Type
conf
DOI
10.1109/FUSION.1993.518319
Filename
518319
Link To Document