DocumentCode :
2983684
Title :
The safety assessment of wind-photovoltaic hybrid power system for afforestation in desertification area
Author :
Oh, D.S. ; Rhie, K.W. ; Moon, J.Y. ; Tuominen, A.
Author_Institution :
Dept. of Safety Eng., Hoseo Univ., Asan, South Korea
fYear :
2010
fDate :
4-6 Oct. 2010
Firstpage :
317
Lastpage :
320
Abstract :
In this paper, we introduce the wind-photovoltaic hybrid power system (WPHPS) installed in Mongolia and the safety assessment for the WPHPS, which was implemented to prevent the failure mode. In order to prevent desertification and build afforestation, two groups of photovoltaic systems were installed in the Gobi desert. One of the generators, which produces 70kW of the power, operates as the power plant for cultivation in this area and another one works with wind power generator. To operate these installed systems effectively, must be implemented the safety assessment. Failure Mode and Effect Analysis (FMEA) was used as a safety assessment method in this study. The 28 of important assemblies of WPHPS were evaluated by FMEA and the results carried out 47 failure modes.
Keywords :
hybrid power systems; photovoltaic power systems; Gobi desert; Mongolia; afforestation; desertification area; effect analysis; failure mode; power 70 kW; safety assessment; wind power generator; wind-photovoltaic hybrid power system; Assembly; Electric shock; Generators; Photovoltaic systems; Safety; Wind power generation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics Conference (BEC), 2010 12th Biennial Baltic
Conference_Location :
Tallinn
ISSN :
1736-3705
Print_ISBN :
978-1-4244-7356-4
Electronic_ISBN :
1736-3705
Type :
conf
DOI :
10.1109/BEC.2010.5630067
Filename :
5630067
Link To Document :
بازگشت