Abstract
This scenario starts with a 1500 hp forced draft fan boiler application in a paper mill powerhouse. It runs well for a year, then the installation is modified and "shaft current" motor bearing problems are identified. The installation (cabling and grounding) issues are corrected, but the bearing problem persists until a shaft grounding brush is installed. Even with the "shaft brush" installed, bearing frosting occurs within several months. This paper attempts to document an example of the "classic" EDM (electrostatic discharge machining) shaft current phenomena that leads to bearing fluting and ultimate failures. It does not cover the theory behind the shaft currents as this has been well covered in many previous papers. While answering several questions concerning this phenomena; many additional questions regarding practical solutions have arisen.
Keywords
electric motors; installation; machine bearings; paper industry; 1500 hp; PWM supply; bearing failures; bearing fluting; case history; electrostatic discharge machining; forced draft fan boiler; installation; motor bearing problems; paper mill powerhouse; shaft currents; Brushes; Cable shielding; Computer aided software engineering; Couplings; Grounding; History; Pulse width modulation; Shafts; Steel; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulp and Paper, 1999. Industry Technical Conference Record of 1999 Annual
Conference_Location
Seattle, WA, USA
Print_ISBN
0-7803-5526-1
Type
conf
DOI
10.1109/PAPCON.1999.779373
Filename
779373
Link To Document