• DocumentCode
    298698
  • Title

    Performance of modular grid connected PV systems with undersized inverters in Portugal and the Netherlands

  • Author

    Kil, A.J. ; van der Weiden, T.C.J.

  • Author_Institution
    Ecofys Consultancy & Res., Utrecht, Netherlands
  • Volume
    1
  • fYear
    1994
  • fDate
    5-9 Dec 1994
  • Firstpage
    1028
  • Abstract
    Preliminary results on the design and performance of three multi-array grid connected PV systems on flat roofs are presented. From the results it can be concluded that inverters can at least be undersized to 65% of the PV peak power without any significant loss of energy production. These results confirm the findings from model calculations carried out as a part of the design process
  • Keywords
    DC-AC power convertors; invertors; photovoltaic power systems; solar cell arrays; solar cells; Netherlands; Portugal; flat roofs; inter-array distance; model calculations; modular grid connected PV systems; multi-array grid connected PV systems; partial shading; undersized inverters; Buildings; Costs; Design optimization; Europe; Inverters; Large-scale systems; Power generation; Power system modeling; Process design; Production systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Energy Conversion, 1994., Conference Record of the Twenty Fourth. IEEE Photovoltaic Specialists Conference - 1994, 1994 IEEE First World Conference on
  • Conference_Location
    Waikoloa, HI
  • Print_ISBN
    0-7803-1460-3
  • Type

    conf

  • DOI
    10.1109/WCPEC.1994.520136
  • Filename
    520136