Title :
Electrode erosion under high current vacuum arcs
Author :
Ji-yan, Zou ; Li-Chun, Cheng
Author_Institution :
Dept. of Electr. Power Eng., Huazhong Univ. of Sci. & Technol., Hubei, China
Abstract :
Electrode erosion was measured under conditions of practical high current and axial magnetic field (AMF). Arc interruptions were made in a demountable vacuum chamber. Electrode erosion was assessed by weighting. It is shown that the rate of electrode erosion with AMF is 39.8 μg/C and that without AMF it is 1.3 mg/C; the anode gains 15 μg/C for diffused arcs
Keywords :
circuit-breaking arcs; magnetic field effects; axial magnetic field; demountable vacuum chamber; high current vacuum arcs; rate of electrode erosion; Anodes; Cathodes; Circuit testing; Current measurement; Electrodes; Magnetic fields; Switches; Vacuum arcs; Vacuum technology; Voltage;
Conference_Titel :
Electrical Contacts, 1989., Proceedings of the Thirty Fifth Meeting of the IEEE Holm Conference on
Conference_Location :
Chicago, IL
DOI :
10.1109/HOLM.1989.77947