    The band period of a controller area network (CAN) interface written in software cannot be less than the time taken for a bit move, bit comparison and count with branch. Such an interface has been demonstrated, and baud rates of 0.5 MHz may be possible
  • Keywords
    computer networks; industrial control; microcontrollers; network interfaces; protocols; CAN protocol; control systems; industrial control network; microcontrollers; software interface; Application software; Code standards; Control systems; Cyclic redundancy check codes; Hardware; Industrial control; Microcontrollers; Microprocessors; Protocols; Switches;