• DocumentCode
    2992945
  • Title

    Symmetrical Normalization of Autocorrelation Function for Multi-Tau Photon Correlator

  • Author

    Lu Wenling ; Liu Wei ; Tan Boxue ; Shen Jin

  • Author_Institution
    Sch. of Electr. & Electron. Eng., Shandong Univ. of Tecnology, ZiBo, China
  • fYear
    2012
  • fDate
    21-23 May 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In view of using symmetrical normalization for smaller deviation than standard normalization for the multi-tau photon correlator in the whole delay time range but need more monitor channels. We suggest employing symmetrical normalization when the lag time larger than 16384 and standard normalization smaller than 16384. Deviation of symmetrical normalization and standard normalization was analyzed, results show that the deviation of symmetrical normalization is smaller in large lag time and have approximate deviation in small lag time. Measurements with standard polystyrene particles of 60 nm, 150 nm and 450 nm, the calculated average deviation and maximum deviation of two normalization estimators are similar in small lag time, but the average and maximum deviation of standard normalization are 19 to 37 times and 35 to 59 times larger than symmetrical in large time. We adopt nonnegative Tikhonov investigate inversion for 60 nm, 150 nm and 450 nm, the results suggest that the particles size distribution of symmetrical normalization is approach to the true particles size distribution in large lag time. Hence, employing symmetrical normalization in the appropriate dynamic range not only reduce the monitor channel, but also improve the statistical accuracy in large delay time range.
  • Keywords
    particle size measurement; photon correlation spectroscopy; polymers; statistical analysis; autocorrelation function; maximum deviation; monitor channels; multitau photon correlator; nonnegative Tikhonov investigate inversion; particles size distribution; polystyrene particles; statistical accuracy; symmetrical normalization; wavelength 150 nm; wavelength 450 nm; wavelength 60 nm; whole delay time range; Correlation; Correlators; Delay; Dynamic range; Monitoring; Photonics; Standards;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photonics and Optoelectronics (SOPO), 2012 Symposium on
  • Conference_Location
    Shanghai
  • ISSN
    2156-8464
  • Print_ISBN
    978-1-4577-0909-8
  • Type

    conf

  • DOI
    10.1109/SOPO.2012.6270457
  • Filename
    6270457