Abstract
A sensitive proton precession scalar magnetometer has been implemented and used for the active compensation of magnetic fields. For establishing a silent environment for SQUID applications, two approaches might be considered, which consist of passive and active magnetic shielding [1]. Each of these two approaches has its own benefits. In active shielding approach, using vector sensors for the active shielding or calibration systems, has a main complication in precise alignment of the sensor and the coils. This is due to the fact that, the sensitivities and offsets of individual sensors, their mutual angular deviations, and the misalignment between the coil and the sensor reference system have to be exactly considered [2]. Because of these complications, scalar magnetometers have an advantage of more accuracy than vector magnetometers in calibration of active shielding. In scalar active compensation system, shielding is based on elimination (compensation) of external magnetic field by applying proper currents through different coils of the system. In this work a magnetic compensation system has been made based on proton precession magnetometer. Proton Precession scalar magnetometer is used for external magnetic field measurement and based on the measured signal, other processing and amplification circuits apply the compensation currents into the coils of the system [3]. The readout circuits of the sensor which is based on measuring of the precession frequency of Hydrogen atoms around the external magnetic field, has been designed with especial noise consideration for increasing SNR for maximum sensitivity. This system is to be used for different SQUID applications which require a very silent magnetic environment. It should be noted that the mentioned system could be also used for the calibration of the coil systems for vector magnetometer calibration.
Keywords
SQUID magnetometers; compensation; hydrogen; magnetic shielding; SQUID based applications; active magnetic field compensation system; active shielding approach; calibration; external magnetic field; hydrogen atoms; precession frequency; proton precession scalar magnetometer; readout circuits; sensitive proton precession scalar magnetometer; silent magnetic environment; vector sensors; Conferences; Decision support systems; Electrical engineering; magnetic compensation; magnetic field calibration; nuclear magnetic resonance; proton precession;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Engineering (ICEE), 2015 23rd Iranian Conference on
Conference_Location
Tehran
Print_ISBN
978-1-4799-1971-0
Type
conf
DOI
10.1109/IranianCEE.2015.7146433
Filename
7146433
Link To Document