DocumentCode :
3004435
Title :
True RMS power detection with high dynamic range
Author :
Klahn, G.
Author_Institution :
MPD Technol. Inc., Hauppauge, NY, USA
Volume :
4
fYear :
1999
fDate :
13-19 June 1999
Firstpage :
1773
Abstract :
All communication systems require some form of output power reporting as a means to manage the power efficiency of the output spectrum. Traditionally, this task has been performed with diode detectors. Diode detectors are non-linear devices and require elaborate compensation techniques to linearize and operate as a true RMS (Root Mean Square) detector over a wide dynamic and temperature range. A true RMS power detection scheme has been developed, which has a 22 dB dynamic range with /spl plusmn/1 dB accuracy and operates over a temperature range of -40/spl deg/C to +80/spl deg/C.
Keywords :
microwave detectors; power measurement; -40 to 80 C; RMS power detector; communication system; dynamic range; temperature range; Circuits; Dynamic range; Envelope detectors; Radio frequency; Schottky diodes; Signal detection; Temperature dependence; Temperature distribution; Temperature sensors; Voltage;