DocumentCode :
300520
Title :
A hybrid failure detection and isolation structure
Author :
Da, Ren ; Lin, Ching-fanlg
Author_Institution :
American GNC Cor., Canoga Park, CA, USA
Volume :
1
fYear :
1995
fDate :
21-23 Jun 1995
Firstpage :
609
Abstract :
A hybrid failure detection and isolation (FDI) structure is presented in the paper. In the structure, a bank of auxiliary Kalman filters, each of them processing a subset of the sensor measurements, are applied to provide high accuracy detection references. The failure detection is then undertaken by checking the consistency between the state estimate of the main Kalman filter and the auxiliaries. Two state propagators are also included in the FDI structure to reliably isolate the failed sensor measurement. The two propagators are alternatively reset with the data of the Kalman filter to increase their accuracy and thereby the failure isolation performance. The failure isolation is realized by testing the consistency between the state estimates of the auxiliary Kalman filters and the state propagator
Keywords :
Kalman filters; fault diagnosis; fault location; state estimation; auxiliary Kalman filters; consistency; failed sensor measurement; high accuracy detection references; hybrid failure detection and isolation structure; sensor measurements; state estimate; state propagators; Aerodynamics; Aerospace testing; Fault detection; Filters; Global Positioning System; Inertial navigation; Noise measurement; Sensor systems; State estimation; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
American Control Conference, Proceedings of the 1995
Conference_Location :
Seattle, WA
Print_ISBN :
0-7803-2445-5
Type :
conf
DOI :
10.1109/ACC.1995.529322
Filename :
529322
Link To Document :