DocumentCode
3005774
Title
Analysis on the direct-driven high power permanent magnet generator for wind turbine
Author
Kim, Ki-Chan ; Lim, Seung-Bin ; Jang, Ki-Bong ; Lee, Sung-Gu ; Lee, Ju ; Son, Yeoung-Gyu ; Yeo, Young-Kil ; Baek, Soo-Hyun
Author_Institution
Dept. of Electr. Eng., Hanyang Univ., Seoul, South Korea
Volume
1
fYear
2005
fDate
27-29 Sept. 2005
Firstpage
243
Abstract
In this paper, the permanent magnet synchronous generator of 1.5 MW output power which is driven directly without gear system is designed by conventional magnetic equivalent circuit method and analyzed by finite element method for verification of design. We analyzed the characteristics of generator like no load, rated load, short circuit condition and demagnetization of permanent magnet. The last, the analysis results of two kinds of rotor types are compared with each other. Especially the THD (total harmonic distortion) of output voltage is examined for the comparison.
Keywords
design engineering; equivalent circuits; finite element analysis; harmonic distortion; magnetic circuits; permanent magnet generators; rotors; synchronous generators; wind turbines; 1.5 MW; THD; direct-driven high power permanent magnet generator; finite element method; gear system; magnetic equivalent circuit method; permanent magnet demagnetization; rotor types; short circuit condition; total harmonic distortion; wind turbine; Circuit analysis; Equivalent circuits; Finite element methods; Gears; Magnetic analysis; Permanent magnets; Power generation; Synchronous generators; Wind energy generation; Wind turbines;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2005. ICEMS 2005. Proceedings of the Eighth International Conference on
Print_ISBN
7-5062-7407-8
Type
conf
DOI
10.1109/ICEMS.2005.202521
Filename
1574754
Link To Document