DocumentCode
3007912
Title
Errors in Electrical Core Loss Measurement for Extremely Small Samples Applicable to Integrated Converters
Author
Lim, M.H.F. ; van Wyk, J.D.
Author_Institution
Bradley Dept. of Electr. & Comput. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA
fYear
2009
fDate
15-19 Feb. 2009
Firstpage
1022
Lastpage
1026
Abstract
Accurate measurement of core loss of low loss magnetic materials in the milliwatts range for high frequency applications is difficult to achieve due to its sensitivity to measurement error especially when measured at high frequencies. Magnitude and phase errors from the oscilloscope, probes/cables, current viewing resistors, phase shift between voltage and current, and noise coupling into measurement probes, which affect the measurement accuracies will be analyzed in detail.
Keywords
electric current measurement; loss measurement; oscilloscopes; power convertors; voltage measurement; current viewing resistors; electrical core loss measurement; integrated converters; magnetic materials; measurement probes; noise coupling; oscilloscope; phase shift; Core loss; Current measurement; Electric variables measurement; Frequency measurement; Loss measurement; Magnetic losses; Magnetic materials; Noise measurement; Phase measurement; Probes;