Abstract :
This paper presents early result of an investigation of partial discharge (PD) properties in vegetable oil-impregnated insulating system. The laboratory experimental investigation simulated common fault conditions in vegetable oil-impregnated paper and pressboard insulating system. PD tests were carried out at elevated temperature to observe possible variation on PD behavior with temperature. In order to investigate the possible differences in measured PD properties, PD data was collected using a PD detector with a variable measurement bandwidth. The experimental results indicated that temperature changes may result in variation of PD properties. The test results also indicated that the measured PD properties also vary with the detector bandwidth.
Keywords :
insulating oils; partial discharge measurement; PD detector; PD properties; PD tests; partial discharges measurement; pressboard insulating system; variable measurement bandwidth; vegetable oil-impregnated insulating system; Bandwidth; Discharges; Insulation; Partial discharges; Temperature; Temperature measurement; Vegetable oils; oil-impregnated insulating system; partial discharge; vegetable oil;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
TENCON 2011 - 2011 IEEE Region 10 Conference
Conference_Location :
Bali
ISSN :
2159-3442
Print_ISBN :
978-1-4577-0256-3
Type :
conf
DOI :
10.1109/TENCON.2011.6129251
Filename :
6129251
Link To Document :
بازگشت