Title :
Simulation of HVDC wall bushing performance under unevenly wetted conditions
Author :
Tang, L. ; Raghuveer, M.R.
Author_Institution :
Dept. of Electr. & Comput. Eng., Manitoba Univ., Winnipeg, Man., Canada
Abstract :
The electric field distributions for HVDC wall bushings with different dry zone lengths are discussed and their critical flashover voltages predicted using an E-field based model. The simulation yields results in good agreement with experimental results. It is shown that some important aspects of wall bushing flashover, such as the U-shaped characteristics of critical flashover voltage versus dry zone length, critical dry zone length, are well reproduced by the simulation
Keywords :
HVDC power transmission; bushings; electric fields; flashover; simulation; E-field based model; HVDC wall bushing performance; U-shaped characteristics; critical dry zone length; critical flashover voltage; critical flashover voltages prediction; dry zone lengths; electric field distributions; unevenly wetted conditions; Circuit simulation; Computational modeling; DC-DC power converters; Equivalent circuits; Flashover; HVDC transmission; Insulators; Predictive models; Surface discharges; Voltage;
Conference_Titel :
WESCANEX 97: Communications, Power and Computing. Conference Proceedings., IEEE
Conference_Location :
Winnipeg, Man.
Print_ISBN :
0-7803-4147-3
DOI :
10.1109/WESCAN.1997.627122