• DocumentCode
    300968
  • Title

    Converter control strategies for reactive power reduction and compensation in ITER

  • Author

    Gaio, E. ; Piovan, R. ; Toigo, V. ; Benfatto, I.

  • Author_Institution
    Gruppo di Padova per Ricerche sulla Fusione, Padova, Italy
  • Volume
    1
  • fYear
    1995
  • fDate
    30 Sep-5 Oct 1995
  • Firstpage
    385
  • Abstract
    A new method for reactive power compensation is proposed and applied to the ITER AC/DC converter units. It requires a capacitor bank permanently connected to the grid and rated for the peak reactive power absorbed from the converter units when controlled in sequential mode and a suitable control strategy which regulates the reactive power demand of the units in order to reduce that delivered by the HV grid. The description of the method and the results of its application to ITER converter units, obtained with a numerical simulation of the system, are reported in the paper
  • Keywords
    AC-DC power convertors; fusion reactor instrumentation; fusion reactors; numerical analysis; reactive power control; HV grid; ITER AC/DC converter units; converter control strategies; fusion reactor; numerical simulation; peak reactive power; reactive power compensation; reactive power demand; reactive power reduction; sequential mode; Bridge circuits; Capacitors; Coils; DC-DC power converters; Numerical simulation; Reactive power; Reactive power control; Shape control; Steady-state; Thyristors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1995. SOFE '95. Seeking a New Energy Era., 16th IEEE/NPSS Symposium
  • Conference_Location
    Champaign, IL
  • Print_ISBN
    0-7803-2969-4
  • Type

    conf

  • DOI
    10.1109/FUSION.1995.534248
  • Filename
    534248