DocumentCode :
3010084
Title :
Implementation of automated minimum resolvable temperature testing
Author :
Orlando, Harold ; Nelson, Neil ; Pappas, Mike ; Scherr, Larry
Author_Institution :
Northrop Corp., Hawthorne, CA, USA
fYear :
1991
fDate :
24-26 Sep 1991
Firstpage :
37
Lastpage :
40
Abstract :
Minimum resolvable temperature (MRT) is a subjective test technique used to demonstrate the performance of thermal imaging sensors with human observers. To measure MRT, an automated test method that is closely related to the traditional MRT testing has been developed. Results of automated MRT testing in the consolidated automated support system (CASS) electrooptical subsystem (EOSS) are presented. The author compares the automated MRT to traditional MRT data from the same thermal imaging sensor, and describes the theory of MRT as it relates to automated testing. The reasons for developing automated MRT testing are explored, as is the motivation for promoting acceptance of this kind of testing
Keywords :
automatic testing; image sensors; infrared detectors; MRT; automated minimum resolvable temperature testing; consolidated automated support system; electrooptical subsystem; human observers; modulation transfer function; thermal imaging sensors; Automatic testing; Bars; Electronic equipment testing; Frequency; Humans; Image sensors; Optical imaging; System testing; Temperature sensors; Thermal sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
AUTOTESTCON '91. IEEE Systems Readiness Technology Conference. Improving Systems Effectiveness in the Changing Environment of the '90s, Conference Record.
Conference_Location :
Anaheim, CA
Print_ISBN :
0-87942-576-8
Type :
conf
DOI :
10.1109/AUTEST.1991.197527
Filename :
197527
Link To Document :
بازگشت