• DocumentCode
    3010245
  • Title

    Neuromorphic algorithm for retinal implants

  • Author

    Bálya, David ; Roska, Botond

  • Author_Institution
    Dept. of Inf. Technol., Pazmany Univ., Budapest
  • fYear
    2005
  • fDate
    16-19 March 2005
  • Firstpage
    171
  • Lastpage
    174
  • Abstract
    The paper focuses on the input transformation for retinal implants. It describes a novel retina model, based on neurobiological measurements. Our modeling approach is neuromorphic, however the primary motivation is to derive an algorithmic skeleton from the animal retina measurements. The on-line, real-time implementation of the algorithm is given for an off-the-shelf stand-alone system, called Bi-I
  • Keywords
    eye; neurophysiology; prosthetics; animal retina; input transformation; neurobiology; neuromorphic algorithm; off-the-shelf stand-alone system Bi-I; retinal implants; Biomedical acoustics; Cochlear implants; Ear; Image restoration; Neuromorphics; Neurons; Optical transmitters; Retina; Signal restoration; Stimulated emission;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Neural Engineering, 2005. Conference Proceedings. 2nd International IEEE EMBS Conference on
  • Conference_Location
    Arlington, VA
  • Print_ISBN
    0-7803-8710-4
  • Type

    conf

  • DOI
    10.1109/CNE.2005.1419582
  • Filename
    1419582