DocumentCode :
3011370
Title :
Influence of the structure dimension of GIS on the partial discharge
Author :
Dengwei Ding ; Wensheng Gao ; Weidong Liu
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear :
2012
fDate :
23-27 Sept. 2012
Firstpage :
958
Lastpage :
962
Abstract :
Partial discharge (PD) monitoring plays an important role in the online maintenance of the gas insulated switchgear (GIS). In recent years, the ultra high frequency (UHF) method for PD detection arouses great interest of many researchers because of the high sensitivity and anti-interference capability. The coupling of UHF signal is the key to the detection of partial discharge in GIS. The structure size of GIS has great impacts on the PD signal, because the cutoff frequency of the high order mode of the electromagnetic (EM) wave depends on the diameters of the inner conductor and enclosure. In this paper, the influence of the inner conductor diameter is investigated by varying the center conductor size. The inner coupler is adopted to receive the partial discharge signal, and two types of PD sources are tested in the experiment. Firstly, the amplitude and the duration of the time domain signal and the frequency spectrum are focused, and their variations with the size of inner conductor are analyzed. Besides that, In order to research the changes of the TEM mode component and the high order mode component, low pass (LP), band pass (BP) and high pass (HP) filters are applied to process the PD signals, and the cumulative energy rates are calculated to indicate the energy distribution. In addition, a simulation using the FDTD method is conducted for comparison with the experimental results, and it indicates that the results of experiment and simulation are almost consistent.
Keywords :
band-pass filters; conductors (electric); finite difference time-domain analysis; gas insulated switchgear; high-pass filters; low-pass filters; maintenance engineering; partial discharges; FDTD method; GIS; PD detection; PD monitoring; PD signal; TEM mode; antiinterference capability; band pass filters; conductor; electromagnetic wave; gas insulated switchgear; high pass filters; inner conductor diameter; low pass filters; online maintenance; partial discharge; structure dimension; ultra high frequency; Conductors; Cutoff frequency; Finite difference methods; Gas insulation; Metals; Partial discharges; Substations; FDTD; frequency spectrum; partial discharge; structure size of GIS; the cumulative energy rate; ultra high frequency;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Condition Monitoring and Diagnosis (CMD), 2012 International Conference on
Conference_Location :
Bali
Print_ISBN :
978-1-4673-1019-2
Type :
conf
DOI :
10.1109/CMD.2012.6416313
Filename :
6416313