Title :
Precise 3D measurements with a high resolution stereo head
Author :
Gasteratos, A. ; Martinotti, R. ; Metta, G. ; Sandini, G.
Author_Institution :
Lab. for Integrated Adv. Robotics, Genoa Univ., Italy
Abstract :
We investigate a method to obtain accurate 3D measurements and we compare it with a standard photogrammetry method. The method utilizes a closed-loop to bring the point under measure in the middle of the two images of a stereo pair. It uses poor calibrated cameras and the accuracy of the measurements relies on the high resolution of the stereo head encoders and on its calibration as well. Experimental results have shown that the proposed method is more accurate than the standard photogrammetry method, as well as it is more robust to small variations of the initial position of the cameras
Keywords :
calibration; cameras; image resolution; legged locomotion; measurement errors; photogrammetry; robot vision; stereo image processing; CAD model; calibrated cameras; camera position variations; closed-loop; high resolution stereo head; legged robot; measurement accuracy; pose estimation; precise 3D measurements; standard photogrammetry method; stereo head encoders; stereo images; Calibration; Cameras; Communication standards; Equations; Head; Laboratories; Machine vision; Measurement standards; Robot kinematics; Robustness;
Conference_Titel :
Image and Signal Processing and Analysis, 2000. IWISPA 2000. Proceedings of the First International Workshop on
Conference_Location :
Pula
Print_ISBN :
953-96769-2-4
DOI :
10.1109/ISPA.2000.914909