• DocumentCode
    3014268
  • Title

    Closing the feedback loop in the half-bridge complementary-control DC-to-DC converter

  • Author

    Linera, F.F. ; Sebastián, J. ; García ; Díaz, J. ; Fontan, A.

  • Author_Institution
    Oviedo Univ., Spain
  • Volume
    2
  • fYear
    1997
  • fDate
    23-27 Feb 1997
  • Firstpage
    977
  • Abstract
    The half-bridge complementary-control converter (HBCC) has been proposed as a good solution for a low-output voltage DC-to-DC converter. A study of the dynamic of this converter using a symmetrical isolation transformer has already been introduced. This paper shows a generalization of the study using an asymmetric transformer. Some practical design rules have been proposed to facilitate the design of the compensation network. Finally, a dynamic study of the peak control current mode is presented
  • Keywords
    DC-DC power convertors; bridge circuits; compensation; electric current control; feedback; transformers; asymmetric transformer; compensation network design; dynamic study; feedback loop closing; half-bridge complementary-control DC-to-DC converter; low-output voltage DC-to-DC converter; peak control current mode; Capacitors; Circuits; DC-DC power converters; Feedback loop; Filters; Inductance; Low voltage; Rectifiers; Stress; Telecommunications;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 1997. APEC '97 Conference Proceedings 1997., Twelfth Annual
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    0-7803-3704-2
  • Type

    conf

  • DOI
    10.1109/APEC.1997.575766
  • Filename
    575766