Title :
Research on Non-Contact Measurement Technology for the Cylindrical Grinder
Author :
Hongge, Sun ; Yi, Cao ; Yi, Zang ; Xin, Yan
Author_Institution :
Coll. of Electr. Eng., Henan Univ. of Technol., Zhengzhou, China
Abstract :
To avoid surface abrasion while measuring the external diameter of the work piece with directly contact measurement, the eddy current sensor based non-contact on line measurement technique for the external cylindrical grinder is proposed. The experiment was carried out with different cylindrical work piece, some features including linearity, resolution and sensitivity were tested and the influence on measurement result with different materials was also discussed. Experiment results show that the proposed non-contact measurement method is feasible for cylindrical grinder, and the precision and efficiency could thus be improved.
Keywords :
eddy currents; grinding machines; materials testing; spatial variables measurement; cylindrical grinder; eddy current sensor; noncontact measurement technology; Current measurement; Eddy currents; Linearity; Measurement techniques; Medical services; System-on-a-chip; cylindrical grinder; eddy current sensor; non-contact;
Conference_Titel :
Electrical and Control Engineering (ICECE), 2010 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-6880-5
DOI :
10.1109/iCECE.2010.424