DocumentCode
3015171
Title
A study on EKC265 bath life and fluorine and carbon contamination on bond pads
Author
An, L.H. ; Lai, K.K. ; Chay, W.Y. ; Hua, Y.N.
Author_Institution
Chartered Semicond. Manuf. Ltd., Singapore
fYear
1998
fDate
1998
Firstpage
9
Lastpage
12
Abstract
A study was conducted on EKC265 cleaning bath life. The Auger analysis technique was used to evaluate the contamination levels of fluorine and carbon on the bond pad after the EKC265 process. The results showed that it is necessary and effective to perform EKC265 cleaning for L95 lots. The contamination levels of C and F on the surface (0 Å) of bond pads were about 20 at% and 7.5 at% at the bath life of 40 lots used currently. However, they were 0 at.% at a depth of 50 Å. The results also show that it is possible to extend EKC265 bath life from 40 lots (6 inch) to 50 lots (6 inch) for cost reduction purposes
Keywords
Auger electron spectra; carbon; fluorine; integrated circuit testing; integrated circuit yield; microassembling; surface cleaning; surface contamination; 50 angstrom; 6 in; Auger analysis techniqu; C; EKC265 bath life; EKC265 cleaning; EKC265 cleaning bath life; F; bath life; bond pads; carbon contamination; contamination levels; cost reduction; fluorine; fluorine contamination; Atherosclerosis; Costs; Electrons; Etching; Fabrication; Failure analysis; Measurement standards; Reliability engineering; Surface contamination; Wafer bonding;
fLanguage
English
Publisher
ieee
Conference_Titel
Semiconductor Electronics, 1998. Proceedings. ICSE '98. 1998 IEEE International Conference on
Conference_Location
Bangi
Print_ISBN
0-7803-4971-7
Type
conf
DOI
10.1109/SMELEC.1998.781140
Filename
781140
Link To Document