DocumentCode
3015558
Title
Automated system for correction of functional state of production workers
Author
Varnavsky, Alexander N.
Author_Institution
Dept. of Inf. & Autom. of Technol. processes, Ryazan State Radio Eng. Univ., Ryazan, Russia
fYear
2015
fDate
21-23 May 2015
Firstpage
1
Lastpage
4
Abstract
The article discusses the creation of automated system for correction of negative functional states of production workers on the basis of application equipment USB-6008 and the programming environment LabVIEW National Instruments. The USB-6008 is used for the removal of bioelectric signals worker whose analysis is a virtual instrument used to assess the presence of negative conditions and issue the necessary corrective action. Describes the version of the implementation of the automated system.
Keywords
medical signal processing; occupational health; virtual instrumentation; LabVIEW national instrument programming environment; USB-6008 application equipment; automated system; bioelectric signal removal; negative functional state correction; production workers; virtual instrument; Fatigue; Instruments; Productivity; Programming environments; Skin; Stress; USB-6008; corrective action; galvanic skin response; the correction of functional state; the negative functional status; virtual instrument;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Communications (SIBCON), 2015 International Siberian Conference on
Conference_Location
Omsk
Print_ISBN
978-1-4799-7102-2
Type
conf
DOI
10.1109/SIBCON.2015.7147315
Filename
7147315
Link To Document