DocumentCode :
3015751
Title :
Rapid 3D Transesophageal Echocardiography using a fast-rotating multiplane transducer
Author :
Nathanail, Kyriakos ; Van Stralen, Marijn ; Prins, Christian ; Van den Adel, Franc ; French, Paddy J. ; De Jong, Nico ; Van Der Steen, Anton F W ; Bosch, Johan G.
Author_Institution :
Thoraxcenter, Erasmus Med. Center, Rotterdam
fYear :
2008
fDate :
2-5 Nov. 2008
Firstpage :
848
Lastpage :
851
Abstract :
3D transesophageal echocardiography (3D TEE) with acquisition gating for electrocardiogram (ECG) and respiration is slow, cumbersome for the patient and prone to motion artifacts. We realized a rapid 3D TEE solution based on a standard multiplane TEE probe, extended with a fast-rotating transducer array (FR-TEE). The fast left-right rotation allows acquisition of sufficient image data from the entire rotation range for the full heart cycle within one breath-hold. No ECG- or respiration-gating is applied. In normal mode, the probe has uncompromised optimal 2D quality. 10 seconds of image data with ECG and angle values are recorded and post-processed with specially developed 4D reconstruction software based on normalized convolution interpolation. High quality 3D images of phantoms were acquired, accurately depicting the imaged objects. Sequences of reconstructed 3D volumes of a cyclic moving (4D) balloon phantom show only minimal temporal artifacts. Preliminary results on 5 open-chest pigs and 3 humans showed the overall anatomy as well as valvular details with good diagnostic accuracy and high temporal and spatial resolution. A bicuspid aortic valve was diagnosed from the 3D reconstructions and confirmed by a separate 2D exam, proving the 3D diagnostic capabilities of FR-TEE.
Keywords :
convolution; echocardiography; image reconstruction; medical image processing; phantoms; ultrasonic transducer arrays; 4D balloon phantom; 4D reconstruction software; ECG; acquisition gating; electrocardiogram; fast rotating multiplane transducer; fast rotating transducer array; image reconstruction; motion artifacts; normalized convolution interpolation; rapid 3D transesophageal echocardiography; Convolution; Echocardiography; Electrocardiography; Heart; Image reconstruction; Imaging phantoms; Interpolation; Probes; Software quality; Transducers; TEE; fast-rotating; interpolation; three-dimensional;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2008. IUS 2008. IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-2428-3
Electronic_ISBN :
978-1-4244-2480-1
Type :
conf
DOI :
10.1109/ULTSYM.2008.0204
Filename :
4803166
Link To Document :
بازگشت