Image-guided refocusing of dual-mode ultrasound arrays (DMUAs)
Author :
Ballard, John R. ; Casper, Andrew J. ; Ebbini, Emad S.
Author_Institution :
Dept. of Electical & Comput. Eng., Univ. of Minnesota, Minneapolis, MN
fYear :
2008
fDate :
2-5 Nov. 2008
Firstpage :
1183
Lastpage :
1186
Abstract :
A major advantage of imaging with dual-mode ultrasound arrays (DMUAs) is the inherent registration between imaging and therapeutic coordinate systems during image-guided surgery which allows for image-based feedback for refocusing the therapeutic beam. Specifically, this capability is critical in image-guided thoracic surgeries where the target is partially obstructed by the rib cage, thus limiting the access and distorting the geometrically focused high-intensity focused ultrasound (HIFU) therapeutic beam. Images obtained with single-transmit focus (STF), in which the therapeutic beam is used at diagnostic levels, allow the user to select target and critical locations for optimizing the power deposition. We have developed an optimal refocusing method that takes advantage of the acoustic window of the intercostals spacing in order to minimize the power deposition over the critical regions (ribs) while maintaining or improving the power deposition at the target location (tumor). The algorithm is verified experimentally with a 64-element 1 MHz DMUA, in an attenuating tissue mimicking phantom (0.5 dB/cm/MHz) with embedded Plexiglas ribs. Thermocouples are used to measure sub-therapeutic temperatures across the ribs and at the target location before, during and after 4 seconds of HIFU exposure for both the geometric focusing and the optimized refocusing while normalizing the driving power for both cases. An increase of normalized temperature (per watt of input power) greater than 50% was observed at the target after refocusing. At the same time, a reduction in normalized temperature rise across the ribs was greater than 70%. Statistics showed that the maximum variance between measurements when the experiment was rerun a minimum of 5 times for each case was approximately 5%. In addition, STF images taken with the refocused HIFU beam showed increased echogenicity at the target and reduced echogenicity at the ribs. This can be quantified by the intensity of the grayscale i- - mages. These images show a typical reduction of 11dB across the ribs. These results show that imaging of the therapeutic beam at diagnostic levels in STF mode correlates with the energy deposition during HIFU treatment.
Keywords :
biomedical ultrasonics; cancer; phantoms; surgery; thermocouples; tumours; ultrasonic arrays; ultrasonic focusing; ultrasonic therapy; DMUA; HIFU therapeutic beam; HIFU treatment; Plexiglas rib; STF mode correlation; acoustic window; dual-mode ultrasound array; echogenicity; frequency 1 MHz; grayscale image; high-intensity focused ultrasound; image-based feedback; image-guided refocusing; image-guided thoracic surgery; optimal refocusing method; rib cage; single-transmit focus; sub-therapeutic temperature measurement; therapeutic coordinate system; thermocouple measurement; tissue mimicking phantom; tumor; Acoustic beams; Acoustic distortion; Feedback; Focusing; Imaging phantoms; Neoplasms; Ribs; Surgery; Temperature measurement; Ultrasonic imaging; Dual-Mode Ultrasound Arrays; HIFU; Refocusing; Therapeutic Ultrasound;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2008. IUS 2008. IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-2428-3
Electronic_ISBN :
978-1-4244-2480-1
Type :
conf
DOI :
10.1109/ULTSYM.2008.0285
Filename :
4803337
Link To Document :
بازگشت